Savaria dealers understand the importance of a safe installation and abide by safety code standards
If you choose an accordion-style or bi-fold gate and pair this with a swing-style landing door, there is a maximum gap that must not be exceeded between the elevator cab gate and the landing door. Known as the ¾" and 4" rule, the hoistway (inside) of the landing door and landing sill cannot exceed ¾", and the distance between the hoistway side of the landing door and cab gate cannot exceed 4 inches.